用于自由运行准谐振操作的 NCP1337 PWM 电流模式
控制器的典型应用。退磁
检测器可确保任何负载/线路条件下的完整边界/临界导通模式以及最小漏极电压开关(准谐振操作)。由于 Soxyless 概念,变压器
磁芯复位检测在内部完成,无需使用任何外部信号。频率内部限制为 130 kHz,防止控制器在高于 150 kHz CISPR-22 EMI 起始限值的情况下运行。通过监控反馈引脚活动,一旦功率需求低于预定水平,控制器就会进入跳跃模式。由于每次重新启动都会通过内部 Soft-Skip 进行软化,并且频率不能低于 25 kHz,因此听不到任何噪音
说明
-
Typical Application for NCP1337 PWM Current-Mode Controller for Free Running Quasi-Resonant Operation. demagnetization detector which ensures full Borderline/Critical Conduction Mode in any load/line conditions together with minimum drain voltage switching (Quasi-Resonant operation). The transformer core reset detection is done internally, without using any external signal, due to the Soxyless concept. The frequency is internally limited to 130 kHz, preventing the controller to operate above the 150 kHz CISPR-22 EMI starting limit. By monitoring the feedback pin activity, the controller enters skip mode as soon as the power demand falls below a predetermined level. As each restart is softened by an internal Soft-Skip, and as the frequency cannot go below 25 kHz, no audible noise can be heard