低功耗多通道
热电偶测量系统是一种灵活的 4 通道、低功耗热电偶测量电路,总功耗低于 8 mW。该电路具有一个多路复用前端,后接一个仪表放大器,用于执行
冷端补偿并将热电偶输出转换为精确比例因子为 5 mV/C 的电压。在 -25 C 至 +400 C 的测量范围内,误差小于 2 C,主要是由于热电偶非线性造成的。非线性校正算法在 900 C 测量范围内将误差降至 0.5 C 以下
说明
-
Low Power multi-channel thermocouple Measurement System is a flexible, 4-channel, low power thermocouple measurement circuit with an overall power consumption of less than 8 mW. The circuit has a multiplexed front end, followed by an instrumentation amplifier that performs cold junction compensation and converts thermocouple output to a voltage with a precise scale factor of 5 mV/C. The error is less than 2 C, over a measurement range of -25 C to +400 C and is primarily due to thermocouple nonlinearity. A nonlinearity correction algorithm reduces the error to less than 0.5 C over a 900 C measurement range