Design Highlights
-No input bulk capacitor
-Improves reliability in areas with severe line voltage fluctuations
-Saves PCB space and reduces cost compared to stacking two electrolytic capacitors for increased voltage rating
-Highly energy effi cient
-Meets CEC/ENERGY STAR 2008 requirements for active mode effi ciency (55% vs 50% requirement)
-Low input power at no-load (<200 mW no-load consumption at 230 VAC vs 500 mW requirement)
-Low cost, low component count, compact, lightweight linear replacement power supply
-No optocoupler required
-No CC sensing resistors required
-Simple EMI fi lter meets EN55022B limits